BD Loop Installation for Asphalt or Gravel Roads, Brick Pavers, or Concrete

AAARemotes > Categories  > BD Loop Installation for Asphalt or Gravel Roads, Brick Pavers, or Concrete

BD Loop Installation for Asphalt or Gravel Roads, Brick Pavers, or Concrete

Directions for quick and easy layout of BD Loops

Step #1

Determine the placement of the yoke (intersection of loop and lead-in wire) and secure it in place. Pace off 8 foot 8 inches at 62° for a 4′ x 8′ or 9 foot 1 inch at 70° for a 3′ x 9′ loop size and ground stake* or cable tie* the corner in place. See Figure A, Step #1 above. Note: BD Loops are packed from the factory with the corner opposite of the yoke with a folded bend in the loop for easy identification

Step #2

Place a stake or cable tie at the 4′ or 3′ leg of the loop that makes a 90° corner as shown below and marked as Step #2.

Step #3

Place the last stake or cable tie to form a 90° corner marked as Step #3 to form a 90° angle. See bottom drawings of Figure A.

* Both ground stakes and cable ties are supplied with each loop.

BD Loops installation under Asphalt or Gravel Road

Step #1

Position and shape the loop on asphalt sub-base.

Step #2

Pull lead-in through ½ inch rigid schedule 40 or 80 PVC from loop yoke to gate operator detector location. Glue all PVC joints.

Step #3

Dig a 2-inch wide by 3-inch deep trench in the size and place of the loop footprint in step #1 and lead-in run to the detector. In the case of a Gravel Road, dig 6 to 8 inches deep.

Step #4

Fill the trench with one inch of sand base.

Step #5

Lay the loop and lead-in run in the trench on top of sand base and use supplied ground stakes to secure the loop corners.

Step #6

Cover loop and lead-in PVC run with 2.5 inches of sand. A slight mound effect will take place in the sand as it covers the loop and lead-in PVC run. This will allow a good compaction of sand around the loop when asphalt is applied.

BD Loops installation under Brick Pavers

Step #1

Determine loop position and footprint to include lead-in run to gate operator.

Step #2

Dig a two-inch wide by three-inch deep trench.

Step #3

Fill trench with 1 inch of sand

Step #4

Place loop in trench and run lead-in through schedule 40 or 80 rigid PVC. Glue all PVC joints.

Step #5

Cover loop and lead-in run with two and one half inches of sand.

BD Loops installation in Concrete

Step #1

Lay loop on top of the rebar (never below) and shape loop into desired loop pattern. Off-set loop pattern two to three inches to the left or right so it does not lie directly on top of rebar pattern.

Step #2

Use cable ties to secure loop in place.

Step #3

Run lead-in below the rebar through schedule 40 or 80 rigid PVC and glue all PVC joints.